HomeNewsIndia News3 Hidden Oscilloscope Specs That Really Matter

3 Hidden Oscilloscope Specs That Really Matter

ABSTRACT

All oscilloscopes are listed with specifications like sampling rate, bandwidth, and voltage range, but are those the best specifications to use when you choose a new instrument? Although these are important pieces of information to have about a new piece of equipment, understanding the quality of an oscilloscope requires reading a little further into the user manual. See why the effective number of bits (ENOB), passband flatness, and -3 dB filter roll-off may be the most important specs you aren’t looking at.

OVERVIEW

ENOB of an oscilloscope is the actual measurement resolution after you have accounted for the distortion, noise effects, and spurs of the instrument. It gives a much more accurate representation of the measurement performance of an oscilloscope than the resolution printed on the front panel or in the data sheet, and it is calculated directly from the signal-to-noise and distortion (SINAD) specification. Noise and device spurs are embedded into the measurements your oscilloscope takes. These add voltage offsets and frequency components that are not part of the signal of interest.

Figure 1. Effective number of bits (ENOB) is a measure of oscilloscope
Figure 1. Effective number of bits (ENOB) is a measure of oscilloscope

Instrument vendors can improve ENOB by using cutting-edge analog-to-digital converters with very low noise density and implementing advanced algorithms for data correction. When choosing a new oscilloscope look for one with a high ENOB, SINAD, or spurious free dynamic range (SFDR) specification to get the best measurement performance. The PXIe-5171R oscilloscope from NI is an example of a 14-bit oscilloscope that has relatively high ENOB (11-bit). NI also offers the industry-leading PXI-5922 flex resolution oscilloscope with 16 to 24-bit resolution and unparalleled spectral performance of up to 105 dB SINAD.Learn more about calculating ENOB and SFDR in the white paper,Understanding Frequency Performance Specifications.

PASS BAND FLATNESS
Don’t assume you are getting consistent amplitude measurements across your oscilloscope’s frequency range. The passband flatness specification is the consistency of amplitude measurements throughout the frequency measurement range of an oscilloscope. An oscilloscope with exceptional flatness will have little change in measured amplitude of the same voltage level at all frequencies it is specified to measure.

Figure 2 . The typical frequency response of an oscilloscope (red) deviates greatly from the ideal, theoretical frequency response (grey) within the operating frequency of the oscilloscope, which can result in inaccurate measurements.
Figure 2 . The typical frequency response of an oscilloscope (red) deviates greatly from the ideal, theoretical frequency response (grey) within the operating frequency of the oscilloscope, which can result in inaccurate measurements.

You can check this by looking at the frequency response Bode plot of the oscilloscope, signal-to-noise ratio or SFDR at multiple frequencies and observing the differences in the numbers, or the flatness specification of an instrument. An instrument with good flatness allows you to make measurements at any frequencies and compare data with minimal correction for frequency, which makes correlation easier and faster.

An example of an oscilloscope with excellent passband flatness is the 1.5 GHz, 10-bit PXIe-5162 oscilloscope. See the Bandwidth and Transient Response section of the  PXIe-5162 specification document.

– 3dB FILTER ROLL OFF
When you use oscilloscopes as precise amplitude or frequency measurement devices, the inclusion of harmonic components and noise spurs can adversely affect measurements. All oscilloscopes have analog bandwidth specifications defined by the -3 dB point, but something that you should be more aware of is how much your measurements are being affected by signals beyond the specified bandwidth. Signals that occur in the extended operating frequencies of an oscilloscope can appear in the region that you are measuring through aliasing. You can combat these effects by using an oscilloscope with anti-aliasing filters for your particular region of interest or by finding an oscilloscope with a sharper filter roll-off, typically about -20 dB per decade.

Figure 3. The bandwidth spec on your oscilloscope doesn’t mean that high-
Figure 3. The bandwidth spec on your oscilloscope doesn’t mean that high- frequency signals disappear. Oscilloscopes with poor -3 dB roll-off performance permit signals from outside of the operating frequency range to Figure 3. The bandwidth spec on your oscilloscope doesn’t mean that high- frequency signals disappear. Oscilloscopes with poor -3 dB roll-off performance permit signals from outside of the operating frequency range to erroneously appear in the measurement spectrum.

An oscilloscope with an excellent low-pass filter response will roll off significantly after the -3 dB point. If the filter does not have adequate roll-off
performance, spectral measurements can be significantly altered by aliased signals in the region of interest.

To learn more about aliasing and the Nyquist theory of sampling, see Acquiring an Analog Signal: Bandwidth, Nyquist Sampling Theorem, and Aliasing.

NEXT STEPS

• Learn about the fundamentals of oscilloscope operation and performance in the Instrument Fundamentals series.
• See all of the oscilloscopes that NI offers and find the one that meets your needs.

 

ELE Times Bureau
ELE Times Bureauhttps://www.eletimes.ai/
ELE Times provides a comprehensive global coverage of Electronics, Technology and the Market. In addition to providing in depth articles, ELE Times attracts the industry’s largest, qualified and highly engaged audiences, who appreciate our timely, relevant content and popular formats. ELE Times helps you build awareness, drive traffic, communicate your offerings to right audience, generate leads and sell your products better.

Related News

Must Read

AI Training vs AI Inference: The War for Faster, Cheaper, and More Efficient AI Computing

Abhishek Pandey/Sub-Editor/ELE Times  Learn how next-generation chip architecture, new hardware,...

Microchip Achieves QML Class V Qualification for RT PolarFire FPGA for Space Applications

Microchip Technology has expanded its radiation-tolerant (RT) PolarFire FPGA...

Vishay Extends Safety-Certified MLCC Portfolio with New 305 VAC Capacitors

Vishay Intertechnology has expanded its VJ Safety Certified Capacitors...

Infineon Partners with Megmeet to Develop 800 VDC Power Solutions for AI Data Centres

Infineon Technologies is working with Shenzhen Megmeet Electrical Co.,...

STMicroelectronics Unveils STM32G5 Microcontrollers for AI Data Centres, Robotics and Real-Time Power Control

STMicroelectronics, a global semiconductor company, has introduced its new...

AutoEV Bharat 2026, Bengaluru: A Must-Visit Show for Automotive OEMs

From intelligent vehicles and automotive semiconductors to advanced batteries...

ASMPT Introduces SIPLACE V L to Expand SMT Placement Platform Capabilities

ASMPT SMT Solutions has expanded its SIPLACE V placement...