HomeTechnologyAutomation and RoboticsIntrinsically safe signal transmission and functional safety combined in one highly compact...

Intrinsically safe signal transmission and functional safety combined in one highly compact package

The EtherCAT Terminals in the ELX series have been expanded by the addition of analog input terminals with TwinSAFE SC (Single Channel) technology. These highly compact I/O terminals can be used to support applications in hazardous areas that require both intrinsically safe signal transmission and functional safety capabilities.

The highly compact ELX series terminals, which are certified in compliance with the specifications of the ATEX and IECEx standards, enable direct connection of intrinsically safe field devices through to Zone 0/20 based on an integrated safety barrier. The new terminal designs extended by TwinSAFE SC technology now also make it possible to achieve a safety level equivalent to PL d/Cat. 3 according to EN ISO 13849-1 or SIL 2 according to EN 62061. In this way, it is possible to use all process data existing in a system for safety technology too, such as to monitor the speed of fans in areas sensitive to explosion hazards, for example.

The new I/Os are available as 12 mm wide terminals with two or four analog input channels for 0/4…20 mA, and for RTD resistance sensors, thermocouples/mV and strain gauges. Furthermore, a single-channel terminal is available for the direct connection of intrinsically safe incremental encoders, which evaluates a diagnostic-enabled NAMUR signal in accordance with IEC 60947-5-6.

TwinSAFE SC technology

With the aid of TwinSAFE SC technology, it is possible to make use of standard signals for safety-related tasks in any network or fieldbus system. The data from a TwinSAFE SC terminal is fed to the TwinSAFE Logic, where it undergoes safety-related multi-channel processing. The data originating from different sources is analysed, checked for plausibility and submitted to a “voting” process.

This is done by certified function blocks such as Scale, Compare/Voting (1oo2, 2oo3, 3oo5), Limit, etc. For safety reasons, however, at least one of the data sources must be a TwinSAFE SC component.

For more information, visit beckhoff.com.

ELE Times Research Desk
ELE Times Research Deskhttps://www.eletimes.ai
ELE Times provides a comprehensive global coverage of Electronics, Technology and the Market. In addition to providing in depth articles, ELE Times attracts the industry’s largest, qualified and highly engaged audiences, who appreciate our timely, relevant content and popular formats. ELE Times helps you build awareness, drive traffic, communicate your offerings to right audience, generate leads and sell your products better.

Related News

Must Read

India Announces Nearly 100 GWh of Domestic Battery-Cell Capacity

India is continuously making efforts to increase its domestic...

Exicom Starts Manufacturing Liquid-cooled EV Charger Modules in India

Exicom Tele-Systems has started production of liquid-cooled AC and...

30th International Symposium on VLSI Design and Test (VDAT 2026) Inaugurated at JIIT Noida

The 30th International Symposium on VLSI Design and Test...

Palo Alto Networks Introduces Frontier AI Critical Defense Program

Palo Alto Networks today announced the Frontier AI Critical...

ROHM to Showcase Application-Focused Power and Analog Solutions at electronica India 2026

ROHM will exhibit at electronica India 2026, South Asia’s...

DNA-Powered Memory Could Cut Computing Energy Use by 100x

​A team of researchers at Penn State University has...

DRDO Spotlights Electronics Warfare and AI at NETRA-2026

The Defence Research and Development Organisation (DRDO) has put...